1. Home
  2. Review
  3. Thermostatic Radiator Valve (TRV)

T32-V32 Thermostatic Radiator Valve (TRV)

This product has been discontinued and removed from our shelves.

Radiator Valve/ Heating System Valve/ Radiator TRV

General
The T32-V32 series thermostatic radiator valves are the combinations of thermostat and valve bodies which are extensively used to control room temperature. The user sets a required temperatureby the knob of the thermostatic radiator controller actuator through the expansion sensor element manually and the system will act accordingly to reach the desired temperature.

These valves have passed European EN215-2004 specialty curve test standards

Specifications
Setpoint: 7~28℃
Material: Fireproof ABS engineering plastic
Valve body: Brass HPb59-1 plating with nickel
Stoke material: Stainless steel 1Cr18Ni9
Body pressure: 1.0Mpa
Max pressure difference: 0.11 Mpa
Medium: Water
Maximum fluid temperature :0~120℃

Instruction
1. Temperature Setting
T32 has wide range of set temperature; you can select any temperature you need. The graduations
on the housing of the controller indicate different temperature set points, following is the corresponding
figure of the room temperature and graduation for reference:
T32-V32 series thermostatic radiator valves is easy to operate. For example, if you want to keep the room temperature at about
20°C, you just need to set scale to "3", the controller will modulate the temperature automatically.

2. Night Setting
In order to improve the comfort and energy saving at night or no people staying in the room, the temperature should be set lower.

3. Ventilation
In winter, if the room requires ventilation for a long time, the controller should be set to the lowest position "※" to save energy.

4. Anti-freezing protection
If there is no people in the room for a long time, the controller should be set to the lowest position "※" to keep the room
temperature around 7℃ and prevent from freezing.

5. Cleanness
The controller should be kept ventilated so as to insure accurately modulation. Use a soft duster cloth to clean the housing.